    Data Acquisition Terminal
    DG8000A Datalogger

    DG8000A Datalogger

      DG800A RTU telemetric datalogger integrates traditional DTU terminal function and 2.5G / 3G / 4G transmission, to achieve data collection, storage, control & transmission function for hydrology, water resources and other applications.

      The datalogger uses high performance industrial 32-bit communication processor and wireless module with embedded real-time operating system as software support platform to provide RS232, RS485, switch input/output and other interfaces for a variety of application requirements for hydrology, water resources and others.

      The product can be widely used in various water conservancy information construction areas, such as hydrology, water resources, water environment, water pollution, mountain torrent disasters, reservoir safety, dam safety remote monitoring and control.


    Model:DG8000A
    Hits:192
    Product Presentation

     DG8000A.jpg

    1. Description

        DG800A RTU telemetric datalogger integrates traditional DTU terminal function and 2.5G / 3G / 4G transmission, to achieve data collection, storage, control & transmission function for hydrology, water resources and other applications.

      The datalogger uses high performance industrial 32-bit communication processor and wireless module with embedded real-time operating system as software support platform to provide RS232, RS485, switch input/output and other interfaces for a variety of application requirements for hydrology, water resources and others.

      The product can be widely used in various water conservancy information construction areas, such as hydrology, water resources, water environment, water pollution, mountain torrent disasters, reservoir safety, dam safety remote monitoring and control.


    2. Features

    Communication Protocol

    u  Standard for data communication of pollution emission auto monitoring system. The upload data is minute data (5 minutes) and hour data.

    u  Transmission Control Protocol (TCP)

     

    Major Functions

    u  Timed acquisition of sensor data

    u  Timed reporting of sensor data

    u  Local download of historical data

    u  Report for battery voltage

    u  Local manual configuration

    u  Remote instruction operation

     

    Product Features

    u  Large data storage capacity: 16MB of data storage space for more than 3 years of data.

    u  Communication: GPRS / CDMA / 3G / 4G.

    u  Low power consumption.

    u  Local configuration: support external LCD / keyboard and serial port configuration.

    u  Remote management: support remote parameter configuration (support platform configuration), remote program upgrade. Provides powerful central management software for easy device management (optional).

    Stable & Reliable

    u  High performance industrial wireless module

    u  High performance industrial 32-bit communication processor

    u  Wide power input (DC 5 ~ 36V)

    u  WDT(Watch Dog Timer) to ensure system stability

    u  RS232 / RS485 interface, built-in 15KV ESD protection

    u  SIM / UIM card interface, built-in 15KV ESD protection

    u  Power interface: built-in reverse-phase protection and overvoltage protection

    u  Antenna interface: lightning protection (optional)

     

    3. Specifications

    Wireless

    Item

    Content

    Wireless module

    Industrial   wireless module

    Standard & Band

    Support   EGSM900/GSM1800MHz dual-band, GSM850/900/1800/1900MHz quad-band (optional)

    Support   GSM phase 2/2+

    Support   GPRS class 10, class 12 (optional)

    Theoretical   Bandwidth

    85.6Kbps

    Transmitting power

    GSM850/900<33dBm

    GSM1800/1900<30dBm

    Receiver sensitivity  

    <-107dBm

     

    Hardware

    Item

    Content

    CPU

    Industrial 32-bit   communication processor

    FLASH

    2MB   (expandable to 8MB)

    SRAM

    512KB   (expandable to 1MB)

    Data Storage Flash

    16MB

     

    Interface

    Item

    Content


     

    Serial port

    2   RS232 and 2 RS485 interface, built-in 15KV ESD protection. Serial parameters   are as follows:

    Data   bits: 8 bits (optional 5,6,7 bits)

    Stop   bit: 1 bit (optional 1.5, 2 bits)

    ECC: no   parity (optional odd /even parity, SPACE and MARK check)

    Serial   port rate: 110~230400bps

    Indicator light

    The   indicator light has the system "SYS" indicator

    Antenna interface

    Standard   SMA female antenna interface, characteristic impedance 50 ohms

    SIM/UIM card interface

    Standard clamshell user   card interface, support 1.8V / 3V SIM / UIM card, built-in 15KV ESD   protection

    Power interface

    Industrial   terminal interface, built-in power reverse-phase protection and overcurrent /   overvoltage protection

    Power switch

    Standard   rocker switch

    Wake-up button

    Universal   touch switch

    Ground terminal

    M4   screw ground protection terminal

    External LCD screen

    192 * 64 dot matrix STN LCD   with keyboard (optional)

     

     

     

     

    Application interface

    4   analog input interface (16-bit AD, support 4-20mA current signal input,   optional 0-5V voltage signal input)

    2-way   switch input interface (optical isolation). Logic 1: wet joint 0-3VDC or dry   joint ON; logic 0: wet joint 5-30VDC or dry joint OFF

    2   relay output interface

    Maximum   switching voltage: 30VDC / 220VAC

    Maximum   switching current: 4A

    Maximum   switching power: 120W / 880VA

    4   controlled output power (output voltage the same as the device power supply   voltage. Default as 12V. Single rated output current: 1A, Total rated current   for 4channels:  2A, built-in   overcurrent protection)

     

    Power supply

    Item

    Content

    Standard   power supply

    DC 12V/1.5A

    Power supply range

    DC 5~36V

    Standby current

    <2mA (12V)

    Working current

    <65mA (12V)

     

     

    Physical characteristics

    Item

    Content

    Housing

    Mental Housing, IP30.   Security isolation between shell and system, especially suitable for   industrial control field

    Dimensions

    180.5*125*25.8 mm (Length x   Width x Height, exclude antennas and mounting parts)

    Weight

    580g (host)

     

    Other conditions

    Item

    Content

    Operating   temperature

    -35~+75oC-31~+167℉)

    Storage temperature

    -40~+85oC-40~+185℉)

    Relative humidity

    95% (No   condensation)

     


      Tags:DG8000A Datalogger
      Home | About | Job | Contact | Guess
      日本成a人片在线观看网址,www日韩中文字幕在线看,亚洲第一成人影院,亚洲欧美日韩一区高清中文字幕 大城县| 兴海县| 织金县| 钟祥市| 莱州市| 合阳县| 会东县| 深水埗区| 梁河县| 张掖市| 玉林市| 扎囊县| 宕昌县| 清远市| 邢台市| 慈溪市| 甘德县| 温宿县| 遵化市| 海盐县| 同仁县| 蒙阴县| 镶黄旗| 扶余县| 贞丰县| 文水县| 东莞市| 武威市| 东山县| 福贡县| 江永县| 九台市| 双桥区| 毕节市| 安顺市| 上饶县| 安仁县| 宁城县| 舒兰市| 金山区| 安阳市| http://444 http://444 http://444 http://444 http://444 http://444